Thank you
to Bruce Edwards from U.K. for help with english terminology
and other lanquage problems.
Palo LISHAK, November 11-th 2005
Complete english version coming soon(I hope). Basic principle
of new propositions in english you can see here>>>
We recommend two classes for
electric sailplanes:
- ENTRY CLASS
- F5J
For both classes we recommend:
1 - No limit on number or type of cells, all types
(NiCd, NiMH, LiIon, LiPol...) are allowed ,
2 - Any type of motor allowed
3 - No limit on motor run time
4 - Only one motor run per flight permitted
5 - Working time 10 minutes (600 seconds = 600 points)
6 - Flying task - As long as possible in the working time
7 - Bonus for precision landing (same as in F3J)
8 - Penalty for duration of motor running
For scoring we measure:
- imput power before start (measured
value " w ")
- flying time of the model (measured
value "G")
- motor running time (measured value"M")
- distance of the model from landing point
(measured value "L")
For interpretation of measured
data we must use following formula:
R = G + L - M . w/W
R=
result in round (points)
G= flying time
from start to landing (seconds=points)
L = poits for
precise landing (points)
M = motor
running time (seconds=points)
w= imput power of power
unit before start (Watt)
W=
value of standard imput power (Watt)
*
*/
- for "entry class" we recommend 100 W as standard
imput power, 200 W max.
- for F5J we recommend 500 W as standard imput power, 1000
W max.
Note:
One example of WATTMETER for modellers with memory you can
see here (HiBox)
EXAMPLE 1 (entry class):
I have Sensor-plus model, 2000 mm wingspann, S400 motor, gear
3:1, 8 cells GP1100.....
I have input power with hot accus (measured before start)
110 W
I use motor for 35 seconds
I have total flying time 8 minutes and 50 seconds (530
seconds)
Landing - distance from LP no more than 2 m (95
points)
My result is
R= 530 + 95 - 35 x 110/100 = 530 + 95 - 35 x 1,1 = 625 - 38,5
= 586,5 points
EXAMPLE 2 (entry class):
I have Sensor-plus model, 2000 mm wingspann, MEGA 16/15 motor,
gear 4:1, 7 cells GP1100.....
I have input power with hot accus (measured before start)
195 W
I use motor for 25 seconds
I have total flying time 9 minutes and 15 seconds (555
seconds)
Landing - distance from LP no more than 5 m (80
points)
My result is
R= 555 + 80 - 25 x 195/100 = 555+ 80- 25 x 1,95 = 635 - 48,75
= 586,25 points
EXAMPLE 3 (F5J):
I have Sensor-plus model, 2000 mm wingspann, CYCLON MINI ELITE
motor/gear, 10 cells GP1100.....
I have input power with hot accus (measured before start)
420 W
I use motor for 14 seconds
I have total flying time 9 minutes and 10 second (550
seconds)
Landing - distance from LP no more than 1 m (100
points)
My result is
R= 550 + 100 - 14 x 420/500 = 555+ 100- 14 x 0,84 = 655 -
11,76 = 643,24 points
EXAMPLE 4 (F5J):
I have TANGO model, 2600 mm wingspann, AXI 2826 motor, 16
cells GP1100.....
I have input power with hot accus (measured before start)
725 W
I use motor for 16 seconds
I have total flying time 9 minutes and 35 seconds (575
seconds)
Landing - distance from LP no more than 3 m (90
points)
My result is
R= 575 + 90 - 16 x 725/500 = 575 + 90- 16 x 1,45 = 665 - 23,2
= 641,8 points
Palo LISHAK, RIVA models hobby team